Home breadcrumbs Patient Monitoring  breadcrumbs Telemetry Monitoring Systems breadcrumbs Cardiac Science Quinton Q-Tel RMS Cardiac Telemetry

Cardiac Science Quinton Q-Tel RMS Cardiac Telemetry

Item #Q-TEL
AvailabilityContact us for availability
Please call for a price.
Available New
Send Page to FriendPrint this page

View Complete SpecificationsQuick Specs!

Quinton Q-Tel RMS

NEW! – Q-Tel is the first DICOM-compatible cardiac rehabilitation system in the market!
The Q-Tel Cardiac Rehabilitation Management System simplifies workflow to allow clinicians to spend more time with patients working on their cardiac rehab programs and less time producing documentation and reports. The system's wireless Pocket Assistant allows you to control session parameters from the floor, and Windows-based software provides familiar icons and an intuitive interface. Forms and reports in the Microsoft Excel file format are easily customizable…

Quinton Q-Tel RMS

NEW! – Q-Tel is the first DICOM-compatible cardiac rehabilitation system in the market!
The Q-Tel Cardiac Rehabilitation Management System simplifies workflow to allow clinicians to spend more time with patients working on their cardiac rehab programs and less time producing documentation and reports. The system's wireless Pocket Assistant allows you to control session parameters from the floor, and Windows-based software provides familiar icons and an intuitive interface. Forms and reports in the Microsoft Excel file format are easily customizable to suit your program's requirements.

The Q-Tel system can link easily to your PACS/HIS/EMR system using industry standard HL7, DICOM, XML, or PDF protocols so you can download patient demographic information and upload session data.
The Q-Tel RMS also offers seamless integration with the Orion Outcomes Data Management System. And you can add the Quinton Q-Exchange option for bi-directional communication with your medical informatics system.

Features

Diagnostic-quality electrocardiogram (ECG / EKG) displays
Wireless Q-Tel Pocket Assistant for controlling cardiac rehabilitation sessions from the floor
Windows-based interface
Forms and reports generated in Microsoft Excel format
Monitors 12 cardiac patients at a single station (up to 32 when networked)
Option to network with HIS and EMR clinical systems
Built-in life-threatening alarms (for asystole, ventricular fibrillation (v-fib) and ventricular tachycardia (v-tach))
22 built-in administrative and clinical reports
Tools to support your American Association of Cardiovascular and Pulmonary Resuscitation (AACVPR) certifications

Benefits

Ease of Use. The Windows-based interface uses familiar drag-and-drop functions, consistent pull-down menus, auto-populating and auto-indexing data fields.

Connectivity. The system links easily to hospital information systems so you can download patient demographic information and upload session data.

Accuracy. The Quinton Q-TEL RMS captures and displays ECG signals with diagnostic accuracy.

Clarity. Simple left-to-right icons match the typical workflow for most cardiac rehab programs, and each program module is accessible with just one click.

Reporting. The Q-Tel RMS 3.1 provides all the reports you need, including Patient Intake Assessment, Patient Care Plan, a Customizable Patient Query Report, and Customized Patient Outcomes Graphs.

Integration. The system integrates seamlessly with the Orion Outcomes Data Management system, the standard for outcome reporting for cardiac rehabilitation.

Reliability. The Q-Tel RMS 3.1 is tested to the highest standards; many of our older systems still going strong after more than 10 years of reliable service.

Support. We provide excellent support and service including a 13-month on-site warranty, 2 days of in-service training, free phone tech support, remote support, and competitively priced service contracts.

SPECIFICATIONS

ECG PERFORMANCE
pplicable standards: AAMI EC-11-1991 for diagnostic ECG (The Q-Tel RMS system meets or exceeds the following performance requirements of AAMI EC-11: gain accuracy, frequency response, CMRR, system noise, dynamic range, and input impedance)

Display and analysis filter: Muscle artifact, baseline wander and 50/60 Hz line. User can turn all filters on or off

ECG DISPLAY
Content: 4, 8 and 12 channel ECG display and alphanumeric data I/O

Display: 3.5 - 8 seconds, depending upon number of channels

Data: ECG traces, heart rate, target heart rate, blood pressure, patient demographics and risk profiles, workload, METs, RPE, patient weight, and other user selectable parameters

Gain: 2.5, 5, 10, 20, 40 mm/mV

Lead groups: 4 and 5 wire lead sets, supporting the standard limb set, limb plus one chest lead, and the modified chest lead

ECG ANALYSIS

Heart rate: Moving median estimate based upon R-R intervals

Alarms: Includes 7 programmable technical alarms and up to 13 programmable arrhythmia alarms with automatic strip print or automatic strip record

POWER REQUIREMENTS: 100/120 VAC 50/60 Hz nominal 2.5 A; 200/240 VAC 50/60 Hz nominal 1.3 A

ENVIRONMENTAL

Operating temperature: 50°F to 90°F (10°C to 32°C)

Operating relative humidity: 20% to 80% non-condensing

Storage temperature: 32°F to 113°F (0°C to 45°C)

Storage relative humidity: 10% to 90% with condensation

Ventilation clearances: Workstation: 6 in (min) behind; Laser printer: 3 in (min) on each side

MASTER TOWER

CPU: Intel compatible PC platform, P4 3.4 GHz processor (min)

RAM: 1 GB (min)

Hard drive: 2x80 GB SATA (min)

SLAVE TOWER AND TURNKEY WORKSTATION

CPU: Intel compatible PC platform, P4 3.4 GHz processor (min)

RAM: 512 MB (min)

Hard drive: 80 GB SATA (min)

DISPLAY:
Color LCD, 1280 x 1024; 19 in or 21 in (483 mm or 533 mm)

KEYBOARD AND MOUSE:

Keyboard: main 101 keys, QWERTY layout; Mouse: optical with magnifying function

X12+ TRANSMITTER

Channel: Easily select any 1 of 64 channels using the function keys

Display: 1.25 in x 0.62 in (3.2 cm x 1.6 cm) LCD display shows live ECG, lead fail, lead quality, power ON/OFF, low battery

Lead Connector: Single-block, 4 or 5 lead

Function Keys: Up/Right, Down and Enter keys for ON, menu navigation and CALL

Frequency Range: WMTS 608 MHz (608.48 MHz to 613.52 MHz) or outside USA: 2400 MHz (2400.96 MHz to 2482.56 MHz)

Patient Isolation:

Positive defibrillation protection in compliance with AAMI standards and IEC 601-2-25

Patient Call Button: Depression of any button while monitoring inserts the call signal into the transmitted data stream

Radiated Power: Does not exceed 0.5 mW

Dimensions (H x D x W):
3.5 in x .98 in x 2.5 in (9.1 cm x 2.5 cm x 6.4 cm)

Weight:
With battery: 4.8 oz (136 g); Without battery: 4.0 oz (114 g)

Battery Type: 1 AA alkaline

Battery Duration: 40 hours (typical)

Data Stream Content: Encoded lead potentials, battery voltage, lead potency or impedance

Sample Rate: 500 samples/second/channel

Pacemaker Spike Detection: 10,000 samples/second/channel at the transmitter. Detected pacemaker spikes are transmitted as part of the encoded data stream and are displayed in all acquired leads.

Environmental: Water resistant, classified according to IEC-601-1 and IEC-601-2-25 as ordinary equipment

RECEIVER

Sensitivity: -100 dBm

Antenna: Dual passive antenna system. Open field range: 100+ meters. Optional powered antenna system available to extend coverage

Channels: 64 channels per receiver for 608 MHz and 2400 MHz systems

Receiver Board: Available as 4 or 8 independent receivers per receiver board. Up to 12 receivers per tower.

Leads: 4 or 5 leads of diagnostic ECG data per receiver

Bandwidth: 0.5 Hz to 100 Hz (min). The ECG bandwidth: determined by transmitter and is diagnostic according to AAMI-EC 11-1991

CHART RECORDER

Recording technique: High-resolution thermal dot array, temperature controlled thermal print head

Printed data: One and two channel ECG waveforms and alphanumeric printing

Speed: 25 mm/sec

Paper: Blank or pre-gridded thermal, ECG grid, 5 cm (2 in) wide rolls

Feed: Continuous from roll

PRINTER

Lazer printer: High volume HP4250N or Low volume HP2015dn

Paper dimensions: 8.5 in x 11 in (US letter) or 210 mm x 300 mm (A4)

Resolution: 600 dpi (minimum)

NETWORK SWITCH

Type: 10/100 (10BASE-T/100BASE-TX)

Interface: RJ-45, 100 ohm, UTP cable

Ports: 8 RJ-45 ports, twisted pair, fixed crossover

MAC address table: 2000 entries

Dimensions (H x D x W):
1.26 in x 3.34 in x 6.93 in (3.2 cm x 8.5 cm x 17.6 cm)

Weight: 0.794 lb (0.36 kg)

EXTERNAL HARD DRIVE

Type: USB 2.0

Speed: 7200 RPM

Media Format/Type: NTFS

Capacity: 320 GB (min)

CD-RW DRIVE

Type: 52/32/52 (min)

Speed: 52X (CD-R burn)/32X (CD-RW burn)/52X (CD-ROM read) (mmin)

Media/media capacity: CD-R (74 min or 80 min)

POCKET ASSISTANT

Model: HP iPAQ 2490 or HP iPAQ 2790

Dimensions (H x D x W):
4.8 in x .59 in x 3.0 in (12.2 cm x 1.5 cm x 7.7 cm)

Weight: 4.8 oz (136 g) (with battery and wireless antenna)

Display: 3.5 in (90 mm) QVGA TFT color 16-bit, touch-sensitive transflective display with 240 x 320 at 65,536 colors resolution

Processor: Intel XScale PXA270 at up to 624 MHz

Memory: RAM: 64 MB SDRAM; ROM: 64 MB Intel StrataFlash ROM

Operating system: Microsoft Windows Mobile 2003 or WM5

Battery: Main: 950-mAh lithium-ion removable rechargeable; Backup: 20-mAh rechargeable nickel metal hydride button cell;
Extended: 1800 mAh lithium-ion removable rechargeable

AC adapter: 100/240 VAC/50/60 Hz

Wireless connectivity: Host interface: CF+; Operating frequencies: 2.4 GHz to 2.497 GHz; Data rate: 1, 2, 5.5, 11 Mbps 802.11b

Range: Up to 120 ft (36.6 m) at 11 Mbps

REPORTS

Outcomes:

11 standard outcomes reports covering individual session results, progressreports, and full disclosure

Administrative:

11 standard reports including daily billing, physician list, patient demographics, and statistical summaries.


OFF-THE-SHELF:

Windows XP, Microsoft Office Basic 2007, Microsoft SQL 2000 (MSDE), Adobe Acrobat Reader 6.0 Cardiac Science recommends installing all Microsoft critical and security updates on an ongoing basis to protect the Q-Tel RMS system from Internet based attacks. Additionally, a commercially available anti-virus software package should be used with Q-Tel RMS. Virus scanning should not be performed on the system when using the Q-Tel RMS application. In all cases, Q-Tel RMS application files must be excluded from the virus scan. Cardiac Science does not recommend installing any other unqualified software on your Q-Tel RMS system.


CARDIAC SCIENCE CORP.:

Q-Tel RMS software, Q-Progress software, Purge/Archive utility, Backup/Restore utility


NETWORKING:

Microsoft compatible networking for file storage, distribution, and e-mail (Novel networks are not supported)


SERVICE:

Cardiac Science field service representative or qualified technician only

APPROVED PERIPHERALS

LCD: 19 in (483 mm) Viewsonic VP191 or VP960; 21 in (533 mm) Viewsonic VP2130

Printer: Low volume HP2015dn; High volume HP4250N

Pocket Assistant (PDA): HP iPAQ HX2490 with extended battery; HP iPAQ HX2790 with extended battery; Dell X30 with extended battery; Dell X51 with extended battery

External Modem: V92/56K Multitech - 5634ZBA-USB-V92

External Hard Disk Drive: 320 GB Iomega - 33653


SOFTWARE ONLY WORKSTATION

Minimum Specifications: Processor: Intel Pentium 4, clock speed 2.4 GHz or faster; System memory: 512 MB (min); USB Ports: 1 for optional USB printer; Parallel port: 1 for HASP software access key; CD drive: 8X or faster; Hard drive: 20 GB (min); Video: 16 MB (min); capable of 16 bit high-color, 1280 x 1024 resolution; Operating system: Windows 2000 Professional, Service Pack 4, or Windows XP Professional, Service Pack 2

View Complete Specifications


Service Directory

Repairs Sales Rentals
Defibrillator Repairs Defibrillator Sales Defibrillator Rentals
EKG Machine Repairs EKG Machine Sales EKG Machine Rentals
Holter Monitoring System Repairs Holter Monitoring System Sales Electrosurgical Unit Rentals
Stress Test System Repairs Stress Test System Sales Fetal Monitor Rentals
Telemetry Monitoring System Repairs Telemetry Monitoring System Sales Infusion Pump Rentals
Cardiac Rehab Treadmills Repairs Cardiac Rehab Treadmills Patient Monitor Rentals
Ultrasound System Repairs Ultrasound System Sales Stress Test System Rentals
Patient Monitoring System Repairs Patient Monitoring System Sales Syringe Pump Rentals
C-Arm Repairs C-Arm Sales Anesthesia Machine Rentals
C-Arm Table Repairs C-Arm Table Sales
Infusion Pump Repairs Infusion Pump Sales
Syringe Pump Repairs Syringe Pump Sales
Fetal Monitor Repairs Fetal Monitor Sales
Pulse Oximeter Repairs Pulse Oximeter Sales
Spirometers Repairs Spirometers Sales
Anesthesia Machine Repairs Anesthesia Machine Sales
Autoclaves|Sterilzers Repairs Autoclaves|Sterilzers Sales
Electrosurgical Unit Repairs Electrosurgical Unit Sales
OR|Procedure Lights Repairs OR|Procedure Lights Sales
OR Table Repairs OR Table Sales
Ultrasonic|Distiller Cleaners Repairs Ultrasonic|Distiller Cleaners Sales
Suction Regulators Repairs Suction Regulators Sales
Suction Units Repairs Suction Units Sales
Medical Cabinets Repairs Medical Cabinets Sales
Supply|Utility Carts Repairs Supply|Utility Carts Sales
Hampers|Receptacles Repairs Hampers|Receptacles Sales
Intravenous Stands Repairs Intravenous Stands Sales
Mayo|Solution Stands Repairs Mayo|Solution Stands Sales
MRI-Safe Equipment Repairs MRI-Safe Equipment Sales
Surgical Scrub Sink Repairs Surgical Scrub Sink Sales
Medical Exam Stools Repairs Medical Exam Stools Sales
Medical Stretcher Repairs Medical Stretcher Sales
Instrument|Back Tables Repairs Instrument|Back Tables Sales
Warming Cabinets Repairs Warming Cabinets Sales