Home . Infusion Devices . Infusion Pumps . B. Braun Outlook 300 Safety Infusion System

B. Braun Outlook 300 Safety Infusion System

Item #: BOUT3
Available Refurbished
  • Description
  • Specifications
  • Support Documents
B. Braun Outlook 300 Safety Infusion System

Improve your ability to monitor safe medication practices

• Improve department efficiency by identifying trends in medication delivery and usage

• Access a real-time view of IV therapy progress for continuous maintenance

• Capture the cost of “lost” doses with an audit that can close the billing loop

Leverage real-time data collected at the point of care for easy use by multiple departments

• Easy integration with existing hospital information systems via open architecture

• Utilizes industry standard 802.11b wireless protocol

• Minimize network traffic and enable easy translation with ASCII data string

• Enable authorized users to access realtime infusion data – from a PDA, at the nursing station, in the pharmacy, or at the pump

• Eliminate the need for externally mounted interface with built-in wireless radio

Improve the quality, safety and efficiency of patient care, without impacting clinical workflow, using wireless communication

• Immediate access to DoseGuard™ dose limit data for continuous safety improvement

• Track medication delivery trends to identify clinical support and training needs

• At-a-glance visualization of vital information concerning patient’s IV therapy

• Focus more time on patient care with automated charting

  • SPECIFICATIONS
  • Mechanism: Volumetric, Positive Pressure Displacement Reservoir
  • Width: 30.5 cm (12 in)
  • Height: 11.4 cm (4.5 in)
  • Depth: 22.2 cm (8.75 in)
  • Weight: 5 kg (11 lbs)
  • Power: 120 VAC, 3A, 60 Hz USA excluding accessories Grounding
  • Resistance: Meets UL Standard 2601-1 Leakage
  • Current: Meets or Exceeds UL Standard 2601-1
  • Battery: 12 V sealed lead-acid battery
  • Battery
  • Operating Time: 2.5 hours ± 30 min. at 125 mL/hr
  • Rate Range: 0.1 to 999.9 mL/hr in 0.1 mL increments
  • Micro Mode: 0.1 to 99.9 mL/hr in 0.1 mL increments
  • Volume to be Infused Range: 0.1 to 9999.9 mL in 0.1 mL increments
  • Variable Occlusion
  • Pressure: 75, 100, 200, 300, 400, 500, and 750 mmHg KVO
  • Rate: 3 mL/hr or selected rate whichever is lower
  • Volumetric Accuracy: ± 5%
  • Alarms: Air-in-Line, Bag Empty, Door Open, Downstream Occlusion, Hold time Exceeded, Low Battery, Plug-in, System Error, Upstream Occlusion, Check Set, DoseGuard™ Alert Memory: Permanent data retention after the pump is turned off unless alternative Data Retention Defaults have been selected in the Biomed Options
  • Tubing: Horizon® Pump Sets
  • Modes/Features: DoseScan,™ Dose Mode with Drug Menu and DoseGuard™ dose limits, Primary and Piggyback Modes, Set Time and Volume, Schedule Next Run, Profile Mode for TPN, Program Mode, q(x) Mode, Site Trend, Variable Occlusion Pressure, Micro Mode, Epidural Mode
  • Laser: Class 2 Per IEC 60825-1*
  • Wireless Radio: 2.4 GHz, 802.11b
  • *Applies to laser barcode scanner.