Home . Infusion Devices . Infusion Pumps . B. Braun Outlook 200 Safety Infusion System

B. Braun Outlook 200 Safety Infusion System

Item #: BOUT2
Available Refurbished
  • Description
  • Specifications
  • Support Document
B. Braun Outlook 200 Safety Infusion System

Bedside Barcode Verification Helps Ensure Everything is Right

• Promotes safer administration practices by reducing manual programming steps using barcoding with patient matching

• Promotes integrated safety by assigning dose limits to scanned drugs

• Promotes easy titration by prompting for the starting dose on “titrate” orders

• Visually indicates dose selection with DoseGuard™ software

The Proper Balance of Safety and Ease of Use

• Easy to learn – Manual operation RATE, VOLUME, RUN – Automatic Dose Rate Calculator – Large, highly visible keys • Reduce nuisance air-in-line alarms with air-trapping cassette • Stackable modular design reduces bedside cord clutter and errors due to channel confusion • Comprehensive line of needle-free administration sets include UV light resistant tubing that protects therapy efficacy

SPECIFICATIONS

Mechanism: Volumetric, Positive Pressure Displacement Reservoir

Width: 30.5 cm (12 in)

Height: 11.4 cm (4.5 in)

Depth: 22.2 cm (8.75 in)

Weight: 5 kg (11 lbs)

Power: 120 VAC, 3A, 60 Hz USA excluding accessories


Grounding

Resistance: Meets UL Standard 2601-1 Leakage

current: Meets or Exceeds UL Standard 2601-1

Battery: 12 V sealed lead-acid battery


Battery

Operating Time: 3 hours at 125 mL/hr

Rate Range: 0.1 to 999.9 mL/hr in 0.1 mL increments

Micro Mode: 0.1 to 99.9 mL/hr in 0.1 mL Volume to be

Infused Range: 0.1 to 9999.9 mL in 0.1 mL increments


Variable Occlusion

Pressure: 75, 100, 200, 300, 400, 500, and 750 mmHg KVO

Rate: 3 mL/hr or selected rate whichever is lower Volumetric

Accuracy: ± 5%

Alarms: Air-in-Line, Bag Empty, Door Open, Downstream Occlusion, Hold time Exceeded, Low Battery, Plug-in, System Error, Upstream Occlusion, Check Set, DoseGuard™ Alert

Memory: Permanent data retention after the pump is turned off unless alternative Data Retention Defaults have been selected in the Biomed Options

Tubing: Horizon® Pump Sets

Modes/Features: DoseScan™, Dose Mode with Drug Menu and DoseGuard™ dose limits, Primary and Piggyback Modes, Set Time and Volume, Schedule Next Run, Profile Mode for TPN, Program Mode, q(x) Mode, Site Trend, Variable Occlusion Pressure, Micro Mode, Epidural Mode

Laser: Class 2 Per IEC 60825-1*

Outlook® 200 Safety Infusion System

*Applies to laser barcode scanner.