Home . Infusion Devices . Infusion Pumps . B. Braun Outlook 100 Safety Infusion System

B. Braun Outlook 100 Safety Infusion System

Item #: BOUT1
Available Refurbished
  • Description
  • Specifications
  • Support Documents
B. Braun Outlook 100 Safety Infusion System

Prevent IV Medication Errors

• Promotes patient safety by helping to avoid accidental under- or overdosing using audible and visual alerts

• Provides flexibility for each care area—ability to customize dose limits to your hospital drug formulary

• Promotes clinician choice with dose limit override when limits are exceeded during manual programming and titration

• Visually indicates dose selection with DoseGuard™ software

The Proper Balance of Safety and Ease of Use

• Easy to learn – Manual operation RATE, VOLUME, RUN – Automatic Dose Rate Calculator – Large, highly visible keys

• Reduce nuisance air-in-line alarms with air-trapping cassette

• Stackable modular design reduces bedside cord clutter and errors due to channel confusion

• Comprehensive line of needle-free administration sets including UV light resistant tubing that protects drug efficacy
SPECIFICATIONS
  • Mechanism: Volumetric, Positive Pressure Displacement Reservoir
  • Width: 30.5 cm (12 in)
  • Height: 11.4 cm (4.5 in)
  • Depth: 22.2 cm (8.75 in)
  • Weight: 5 kg (11 lbs)
  • Power: 120 VAC, 3A, 60 Hz USA excluding accessories
  • Grounding
  • Resistance: Meets UL Standard 2601-1 Leakage
  • current: Meets or Exceeds UL Standard 2601-1
  • Battery: 12 V sealed lead-acid battery

  • Battery Operating
  • Time: 3 hours at 125 mL/hr
  • Rate Range: 0.1 to 999.9 mL/hr in 0.1 mL increments
  • Micro Mode: 0.1 to 99.9 mL/hr in 0.1 mL increments Volume to be
  • Infused Range: 0.1 to 9999.9 mL in 0.1 mL increments

  • Variable Occlusion
  • Pressure: 75, 100, 200, 300, 400, 500, and 750 mmHg KVO
  • Rate: 3 mL/hr or selected rate whichever is lower Volumetric
  • Accuracy: ± 5%
  • Alarms: Air-in-Line, Bag Empty, Door Open, Downstream Occlusion, Hold time Exceeded, Low Battery, Plug-in, System Error, Upstream Occlusion, Check Set, DoseGuard™ Alert
  • Memory: Permanent data retention after the pump is turned off unless alternative Data Retention Defaults have been selected in the Biomed Options
  • Tubing: Horizon® Pump Sets
  • Modes/Features: Dose Mode with Drug Menu and DoseGuard™ dose limits, Primary and Piggyback Modes, Set Time and Volume, Schedule Next Run, Profile Mode for TPN, Program Mode, q(x) Mode, Site Trend, Variable Occlusion Pressure, Micro Mode, Epidural Mode