GE Marquette Dash 2000 Patient Monitor
View Complete SpecificationsQuick Specs!
Portable Monitoring value with GE Marquette sophistication...
The DASH 2000 delivers the sophistication and reliability customers have come to expect from us. Plus, it offers the affordability that modest budgets demand.
Weighing no more than 12 pounds, regardless of configuration, this lightweight monitor is made to move with a patient. The compact, ergonomic package, complete with integral power supply, allows easy handling. And drop-test rugged design means the DASH 2000 is made to withstand your demanding portable applications.
While you can configure…
Portable Monitoring value with GE Marquette sophistication...
The DASH 2000 delivers the sophistication and reliability customers have come to expect from us. Plus, it offers the affordability that modest budgets demand.
Weighing no more than 12 pounds, regardless of configuration, this lightweight monitor is made to move with a patient. The compact, ergonomic package, complete with integral power supply, allows easy handling. And drop-test rugged design means the DASH 2000 is made to withstand your demanding portable applications.
While you can configure the DASH 2000 with only those features you really need, it may surprise you just how many performance features are available.
Standard features include 3 and 5-lead ECG, respiration, SpO2, NBP and 1 Temperature. Lethal arrhythmia analysis, with up to 24-hour trending, offers enhanced clinical decision support. And the Trim Knob� provides a convenient, familiar interface to reduce learning curve and maximize clinician efficiency as they move from one GE Marquette Medical Systems monitor to the next.
When it comes to the display, we give you the choice of color or monochrome. Either way, the screen accommodates all numerics and up to 3 waveforms.
Dash 2000 Specifications
As part of the new DASH family of monitors, the DASH 2000 is field upgradable and expansion enabled to leverage your investment over time. To ensure continuity of care, it features 2-way, hard-wired networking standard. A built-in 2-way, wireless networking option expands monitoring versatility. Also, the ability to import and export Admit/Discharge/Transfer information enhances staff efficiency by eliminating redundant data entry.
In addition, the DASH 2000's smart battery management system provides 3-4 hours of uninterrupted operation. And it can be internally recharged in just 1-4 hours.
Dash 2000 Monitor Specifications
Performance Specifications
Display
Size: 5.8-inch (diagonal)
Type: Monochrome LCD; optional color LCD
Resolution: 320 by 240 pixels
Number of traces: 3
Number of seconds/trace: 3.8 at 25 mm/sec
Sweep speed: 25 mm/sec (with erase bar)
Information window: Displays non-real-time information without obstructing the display of real-time information Display organization: Prioritized by parameter
Controls
Trim Knob control
Five hard keys: Silence Alarm, Graph Go/Stop, NBP Go/Stop, Function, and Power On/Off
Alarms
Categories: Patient status and system status
Priority: 4 levels - Crisis, Warning, Advisory, Message
Notification: Audible and visual
Setting: Default and individual
Silencing: 1 minute, current alarm only
Pause: 5 minutes in Adult ICU mode, 3 minutes in Neonatal ICU mode, and 5 minute, 15 minute, or permanent pause in OR mode
Volume: Default 70%, 70 dB measured at 1 meter
ECG
Standard leads available: I, II, III, V, aVR, aVL, and aVF
Leads analyzed simultaneously: I, II, III, and V (multi-lead mode)
Lead fail: identifies failed lead
Alarms: User-selectable upper and lower heart rate limits
Input specifications
Voltage range: � 0.5 mV to � 5 mV
Signal width: 40 ms to 120 ms (Q to S)
Heart rate range: 30 to 300 bpm
Input impedance:
Common mode: > 10 M* at 50/60 Hz
Differential: > 2.5 M* from dc to 60 Hz
Common mode rejection: 90 dB minimum at 50 or 60 Hz
Output specifications
Frequency response:
Display:
Diagnostic: 0.05 to 40 Hz
Monitoring: 0.05 to 40 Hz
Moderate: 0.05 to 25 Hz
Maximum: 5 to 25 Hz
Paper:
Recorder:
Diagnostic: 0.05 to 100 Hz
Monitoring: 0.05 to 40 Hz
Moderate: 0.05 to 25 Hz
Maximum: 0.05 to 25 Hz
Noise: < 30 �V (referred to input)
Pacemaker detection/rejection
Input voltage range: � 2 mV to � 700 mV
Input pulse width: 0.1 ms to 2 ms
Rise time: 10 �s to 100 �s
Over/under shoot: 2 mV (max)
Baseline drift: < 0.5 mV per hour with a � 700 mV, 2-ms pacemaker pulse applied
Respiration
Measurement technique: Impedance variation detection
Range:
Respiration rate: 0-200 breaths per minute
Base impedance: 100-1000 * at 52.6 kHz
Detection sensitivity: 0.4 to 10 * variation
Waveform display bandwidth: 0.1 to 1.8 Hz (-3dB)
Alarms: User-selectable upper and lower respiration rate limits and apnea limit
Temperature
Number of channels: 1
Input specifications
Probe type: YSI Series 400
Temperature range: 0�C to 45�C (32�F to 113�F)
Resolution: � 0.1�C
Output specifications
Parameters displayed: TP
Accuracy: (independent of source) � 0.1�C
Alarms: User-selectable upper and lower limits
Noninvasive Blood Pressure
Measurement technique: Oscillometric
Displayed parameters: Systolic, diastolic, and mean pressures, pulse rate, time of last measurement
Measurement modes: Manual, auto, and stat in Adult ICU and OR modes; manual and auto in neonatal mode
Heart rate detection: 30 to 300 beats per minute
Total cycle time: 20 to 40 seconds typical (dependent on heart rate and motion artifact)
Automatic cycle times: 0 to 24 hours
Auto zero: Zero pressure reference prior to each cuff inflation
Tubing length: 12 feet adult, 8 feet neonatal
Automatic cuff deflation: Cycle time exceeding 3 minutes (90 seconds neonatal), power off, or cuff pressure exceeds: 294 mmHg (�6 mmHg) adult, 147 mmHg (�3 mmHg) neonatal
Cuff sizes:
Disposable: Large adult, adult, small adult, pediatric, small pediatric, and infant
Reusable: Thigh, large adult, adult, child, and infant
Alarms: User-selectable upper and lower limits for systolic, diastolic, and mean pressures
Pressure accuracy (static): �2% or �3 mmHg, whichever is greater
Pressure accuracy (clinical use): �5 mmHg average error 8 mmHg standard deviation
Pulse Oximetry
Parameters monitored: Arterial oxygen saturation (SpO2) and peripheral pulse rate (PPR)
SpO2 range: 50 - 100%
PPR range: 20 - 250 beats per minute (� 3 beats per minute)
Accuracy: Actual accuracy depends on probe. Please reference manufacturer's specifications.
SpO2: � 2% (70 - 100% SpO2) � 3% (50 - 69% SpO2)
PPR: � 3 beats per minute
Alarms: User-selectable upper and lower limits for SpO2 and PPR
Paper Recorder (Option)
Method: Thermal dot array
Horizontal resolution: 480 dots/in @ 25 mm/sec
Vertical resolution: 200 dots/in
Number of waveform channels: three
Paper width: 50 mm (1.97 in)
Paper length: 25 m (95 ft)
Paper speed: 0.1, 0.5, 1, 5, 10, 12.5, 25, and 50 mm/sec (�2%)
Analog Output
ECG
Gain: 1 V/mV � 10%
DC offset: � 100 mV (max)
Noise: < 5 mV peak to peak dc to 300 Hz
Frequency response: 0.05 Hz to 100 Hz -0/+7 Hz
Internal Battery
Battery type: Nickel-cadmium (Ni-Cd)
Charge time: 1 to 4 hrs
Run time: 3 to 4 hrs
Environmental Specifications
Power requirements: 90-264 VAC 50/60 Hz 500 mA
Power consumption: 40 W (fully loaded)
Cooling: convection
Heat dissipation: 135 Btu/hr (max)
Operating Conditions
Ambient temperature: 10 to 40�C (50 to 104�F)
Relative humidity: 5 - 95% @ 40�C
Storage Conditions
(do not exceed):
Temperature: -25 to 70�C (-13 to 156�F)
Relative humidity: 15 to 95%
Physical Specifications
Height: 22 cm (8.5 in)
Depth: 20 cm (8 in)
Width: 27 cm (10.5 in)
Weight: 5.5 kg (12 lb) with all options