Criticare 8100 Poet Plus Vital Signs Monitor
View Complete SpecificationsQuick Specs!
Poet Plus® 8100 is the perfect choice for busy departments demanding maximum flexibility, unsurpassed ease of use, and accurate, reliable performance. Respond to every monitoring need, from standard vital signs to conscious sedation. Monitor adults, pediatrics, and neonates in virtually every department, at bedside or in transit. The Poet Plus 8100 mounts quickly and easily to walls, roll stands, and bedrails.
With the compact, lightweight Poet Plus 8100, you focus on your patients, not your monitor. The innovative user interface with simple, one-level…
Poet Plus® 8100 is the perfect choice for busy departments demanding maximum flexibility, unsurpassed ease of use, and accurate, reliable performance. Respond to every monitoring need, from standard vital signs to conscious sedation. Monitor adults, pediatrics, and neonates in virtually every department, at bedside or in transit. The Poet Plus 8100 mounts quickly and easily to walls, roll stands, and bedrails.
With the compact, lightweight Poet Plus 8100, you focus on your patients, not your monitor. The innovative user interface with simple, one-level menus and dedicated function keys ensures super-fast set-up. The big, bright display with large numerics is easily seen, even from across the room.
Custom Configurations
▣ Standard: ECG, ComfortCuff™ NIBP, DOX™ SpO2, HR, Temperature, Respiration, and Nurse Call interface connection.
▣ Optional: CO2, CO2/O2, IBP (2 channel), and printer.
Features & Benefits
▣ Easy-to-read 10.4" active TFT color display - view up to 6 waveforms simultaneously.
▣ Easy to learn, easy to use menus, dedicated function keys, and simplified controls.
▣ Smart battery management with rechargeable "hot-swappable" sealed lead acid batteries.
▣ Lightweight design and versatile mounting options - adapts readily to department and transport requirements.
OPTION:
Criticare Connect Bluetooth Link
SECURE | RECHARGEABLE NiMH BATTERY | LONG RANGE
Eliminate wire clutter with a secure, reliable Bluetooth connection, linking your patient monitor to your PC workstation.
Technical Specifications
▣ ECG
▣ Connectors: 3- or 5-lead
▣ Leads: User-selectable; I, II, III, aVR, aVL, aVF, V (5-lead); I, II, or III (3-lead)
▣ Gain Selection: 1/2mV, 2mV, 4mV
▣ Frequency Response: Diagnostic: 0.05 to 100 Hz (-3db); Monitor: 0.5 to 40 Hz (-3db)
▣ Sweep Speed: 12.5, 25, 50mm/sec
▣ Electrosurgery Protection: Yes
▣ Defibrillator Protection: Yes
▣ Pacer Detection/Rejection: Yes
Non-Invasive Blood Pressure
▣ Technique: Oscillometric measure upon inflation
▣ Automatic Measurement Cycles: 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
▣ Measurement Range: Adult: 30 to 300mmHg; Neonate: 0 to 150 mmHg
▣ Resolution: 1mmHg
▣ Transducer Accuracy: ±2mmHg or ±2% of reading, which ever is greater, over full range
▣ STAT mode: 5 min of consecutive readings
Pulse Oximetry
▣ Range: 1% to 99%
▣ Resolution: 1%
▣ Accuracy: 70% to 99% range: ±2%; 50% to 69% range: ±3%; <50%: unspecified
▣ Method: Dual wavelength LED
Heart (Pulse) Rate
▣ Source: ECG (primary); IBP, Pleth; NIBP
▣ Range: 20 to 300bpm
▣ Accuracy: ±1bpm or ±1% (ECG, IBP, SPO2 only)
Temperature
▣ Channels: 2
▣ Range, Accuracy: 68° to 94.8° F (20° to 34.9° C): ±0.5%; 95° to 107.4° F (35° to 41.9° C): ±0.2%; 107.6° to 113° F (42° to 45° C): ±0.5%
▣ Probe: YSI-400 and YSI-700 series
Respiration
▣ Rate: 6 to 150 breaths/min
▣ Resolution: 1 breath/min
▣ Accuracy: ±1% or ±1 breath/min, whichever is greater
▣ Source: User selectable: Smart, CO2, ECG-TTI
CO2
▣ Units: mmHg; Torr; %; kPa
▣ Waveform Scale: 0 to 3.13%, 0 to 6.25%, 0 to 12.5% and 0 to 25%
▣ Method: Non-dispersive infrared; auto calibrating
▣ N2O Compensation: Manual; On/Off, user selectable
▣ Range: 0 to 99mmHg; 0 to 99 Torr; 0 to 12.5%; 0 to 12.5 kPa
▣ Resolution: 1mmHg; 1 Torr; 0.1%; 0.1 kPa
▣ Sample Rate: Sidestream, selectable: 150ml/min or 50ml/min
▣ Accuracy: +2mmHg, ±0.3 volume %, ±0.3 kPa, or ±2 Torr at 150ml/min and respiratory rate of ±35 breaths/min
▣ Rise Time: 350ms at 150ml/min (10 to 90%)
O2
▣ Numeric Display: Inspired, expired Method: Oxidation-reduction galvanic cell
▣ Resolution: 1%
▣ Range: 0 to 100%
▣ Accuracy: ±3% volume %
▣ Rise Time: 600ms at 150ml/min (10 to 90%)
Invasive Blood Pressure
▣ Channels: 2
▣ Transducer Sites: Selectable; ART, PA, LA, RA, CVP, ICP
▣ Pressure Range: -10mmHg to 300mmHg
▣ Zero Offset: ±150mmHg
▣ Frequency Response: 0 to 20 Hz
▣ Transducer Sensitivity: 5µV/V/mmHg
▣ Zero: Menu-driven
▣ Accuracy: ±1mmHg or ±1%, whichever is greater
▣ Scale Range: -10 to 10, 0 to20, 0 to 30, 0 to 40, 0 to 60, 0 to 100, 0 to 150, 0 to 200, 0 to 300
Alarms
▣ Indication: Audible; visual (EN475)
▣ Silence: Yes; 2 min or permanent
Trend Memory
▣ Tabular: 24 hr at 30 sec intervals
Display
▣ Screen: 10.4" active color TFT
▣ Resolution: 640 x 480 pixels
▣ Waveforms: 6, maximum
▣ Languages: English, French, German, Italian, Portuguese, Spanish
Controls
▣ Keys: 9; membrane-activated
▣ Rotary Knob: Push and rotate; 24 steps/turn
System Outputs
▣ Com Ports: RS 232-compatible; digital or analog; DB9 (Com 1); mini-din analog (Com 2)
▣ Nurse Call: Contact switch; 3.5mm stereo phone jack, standard 14mm length
▣ Defib/Sync: BNC connector
▣ Video Port: High density D-sub 15-pin
Recorder
▣ Type: Thermal line printer
▣ Paper Speed: 12.5, 25, 50mm/sec
Mechanical
▣ Weight: Base unit without batteries: 12 lb; 5.45kg
▣ Size: Base unit: 13.25" (H) x 12.5" (W) x 8.75" (D); 33.65cm (H) x 31.75cm (W) x 22.22cm (D)
Power Requirements
▣ Voltage: 100, 120, 220, 240 VAC; 50/60 Hz
▣ Consumption: 35 W, typical
▣ Batteries: 2; sealed lead acid; life: 2 hr, typical; recharge time: 4.5 hr
(Base unit without printer or CO2)
Environmental
▣ Operating Temperature: 59° to 95° F; 15° to 35° C
▣ Storage Temperature: 23° to 122° F; -5° to 50° C
▣ Operating Humidity: 15% to 90%, non-condensing
Classification
▣ Types of Protection: Class I equipment
▣ Degree of Protection: Type CF defib-proof
▣ Safety: EN 60601-1
Accessory Information
81C000X Monitor (Standard)
81C001X Monitor (CO2)
81C005X Monitor (CO2/O2)
81C024X Monitor (IBP)
81C025X Monitor (IBP/CO2)
81C028X Monitor (IBP/CO2/O2)
81C000P Monitor (Standard with Printer)
81C001P Monitor (CO2 with Printer)
81C005P Monitor (CO2/O2 with Printer)
81C024P Monitor (IBP with Printer)
81C025P Monitor (IBP/CO2 with Printer)
81C028P Monitor (IBP/CO2/O2 with Printer)
All models come with SpO2/NIBP/ECG and two temperature channels.
SPO2 ACCESSORIES
Reusable Sensors Catalog Number Description
934-10DN Adult Reusable Finger Sensor 10 ft.
934SDN Finger Sensor 3 ft. DB-9
940SD Reusable Multi-Site Sensor 3 ft. Kit**
518DD SpO2 Extension Cable 10ft.
** Multi-site sensor kits include: forehead applicator, headband, ear clip, double-sided adhesives, microfoam tape.
Multi-Site Sensor Accessories
Catalog
Number Description
514 Ear Clip Attachment
525 Double Sided Adhesive Dots (Pkg. of 50)
526 Microfoam Tape (4" strips - Pkg. of 14)
920 Posey Wraps with Holes (Pkg. of 12)
Adhesive Sensors
Adhesive sensors require a 10ft. SpO2 Extension Cable Cat. No. 518DD
Catalog
Number Description
570SD Adult Fabric Adhesive Sensors
571SD Pediatric Fabric Adhesive Sensors
572SD Infant Fabric Adhesive Sensors
573SD Neonatal Fabric Adhesive Sensors
570SDM Adult Foam Adhesive Sensors
571SDM Pediatric Foam Adhesive Sensors
572SDM Infant Foam Adhesive Sensors
573SDM Neonatal Foam Adhesive Sensors
ECG ACCESSORIES
Catalog
Number Description
1073/S 3 Lead Snap ECG AHA Cable Assembly
1073/P 3 Lead Pinch ECG AHA Cable Assembly
1075/S 5 Lead Snap ECG AHA Cable Assembly
1075/P 5 Lead Pinch ECG AHA Cable Assembly
1073/IS 3 Lead Snap ECG IEC Cable Assembly
1073/IP 3 Lead Pinch ECG IEC Cable Assembly
1075/IS 5 Lead Snap ECG IEC Cable Assembly
1075/IP 5 Lead Pinch ECG IEC Cable Assembly
527 ECG Electrodes (Set of 3)
527/5 ECG Electrodes (Set of 5)
1094/3 3 Lead Cable Neonatal/Pediatric - DIN Style 0.60
1094/5 5 Lead Cable Neonatal/Pediatric - DIN Style 0.60
1095/3/25 3 Neonate/Pediatric Pre-wired Electrodes - DIN Style 0.60, Disposable electrode for Cat. No. 1094/3 (package of 25)
1095/5/25 5 Neonate/Pediatric Pre-wired Electrodes - DIN Style 0.60, Disposable electrode for Cat. No. 1094/5 (package of 25)
NIBP ACCESSORIES
Hoses
Catalog
Number Description
705 NIBP Hose - 4 ft. Straight Adult Quick Connect
706 NIBP Hose - 10 ft. Straight Adult Quick Connect
707 NIBP Hose - 10 ft. Coiled Adult Quick Connect
708 NIBP Hose - 4 ft. Straight for Neonate Quick Connect/ Clippard
714 NIBP Hose - 4 ft. Coiled Adult Quick Connect
Reuseable Cuffs
Catalog
Number Description
473 Infant Blood Pressure Cuff (10-19 cm)
474 Child/Small Adult Blood Pressure Cuff (18-26 cm)
475 Adult Blood Pressure Cuff (25-35 cm)
476 Large Arm Blood Pressure Cuff (33-47 cm)
477 Thigh Blood Pressure Cuff (44-66 cm)
Disposable Cuffs
Catalog
Number Description
740 NIBP Cuff 3-6 cm (Pkg. of 10)
741 NIBP Cuff 4-8 cm (Pkg. of 10)
742 NIBP Cuff 6-11 cm (Pkg. of 10)
743 NIBP Cuff 7-13 cm (Pkg. of 10)
744 NIBP Cuff 8-15 cm (Pkg. of 10)
745 NIBP Cuff Infant (Pkg. of 10)
746 NIBP Cuff Child (Pkg. of 10)
747 NIBP Cuff Small Adult (Pkg. of 10)
748 NIBP Cuff Adult (Pkg. of 10)
749 NIBP Cuff Large Arm (Pkg. of 10)
750 NIBP Cuff Thigh (Pkg. of 10)
TEMPERATURE PROBES
Reuseable Probes
Catalog
Number Description
420 General Purpose Rectal/Esophageal
421 Banjo Style Probe
422 Skin Surface Probe
Disposable Probes
Catalog
Number Description
437 Skin Surface Probe
438 General Purpose Rectal/Esophageal
439 Temperature Interconnect Cable
440 Temperature Starter Kit (1 ea. 439, 438, 437)
GAS MONITORING ACCESSORIES
Sampling Devices
Catalog
Number Description
625N Sample Lines (Box of 25)
624 Disposable Nasal Cannula (Box of 10)
628 Divided Nasal Cannula (Box of 10)
616 Endotracheal Adaptor, Straight (Box of 10)
617 Endotracheal Adaptor, Elbow (Box of 10)
938F-NC WaterChek 2+, Water Trap (Box of 30)
644 Replacement O2 Cell
655 Scavenging Kit (Exhaust Line & Adaptor)
655-1 Scavenging Kit (Exhaust Line & Adaptor) International
CALIBRATION ACCESSORIES
Catalog
Number Description
621 Cal Gas (5% CO2, Balance N2)
622 Cal Gas (10% CO2, Balance N2)
716 Cal Gas (95% O2, Balance CO2)
620 Cal Gas (100% N2)
623 Regulator For Cylinder
613 Regulator Tubing
641 Cal Gas Aerosol (5% CO2, Bal N2)
642 Cal Gas Aerosol (10% CO2, Bal N2)
Calibration Kits
Catalog
Number Description
612 CO2 only (Non-Anesthetic Agent); 5% CO2 cylindar, 10% CO2 cylindar, regulator with tubing, plastic storage case.
715 CO2 and O2 (Non-Anesthetic Agent); 5% CO2 cylindar, 10% CO2 cylindar, 95% O2 cylindar regulator with tubing, plastic storage case.
OTHER ACCESSORIES AVAILABLE
Catalog
Number Description
553 Printer Paper (10 Rolls) P/N 40065B0O2
P/N 83278B001 Battery
P/N 42194B001 Adapter Plate (GCX Mounting)
CT-0024-01 GCX Wall Mount (Does not include wall channel & adapter plate)
CT-0024-03 GCX Wall Mount and Channel (Does not include adapter plate)
CT-0024-60 GCX Roll Stand and Adapter Plate
1092 Carry Case
909 Power Cord (Domestic US)
910UK Power Cord (United Kingdom)
910INT Power Cord (International)
910 Unterm Power Cord (Unterminated)
603 Japan Power Cord (Japan)