Criticare 8500 Poet IQ2 Anesthetic Gas Monitor
View Complete SpecificationsQuick Specs!
Powerful and compact—fits into small shelves on gas kits and is an excellent choice for updating existing anesthesia delivery systems with state-of-the-art agent detection and proprietary 5-agent gas analysis technology.
The Poet IQ2® Anesthetic Gas Monitor provides an affordable solution for 5-agent gas monitoring in any operating environment. The Poet IQ2 has an external video output port that is compatible with VGA flat screen displays, allowing patient data to be displayed where the surgical team needs to see the information. The anesthetic monitor comes with an internal…
Powerful and compact—fits into small shelves on gas kits and is an excellent choice for updating existing anesthesia delivery systems with state-of-the-art agent detection and proprietary 5-agent gas analysis technology.
The Poet IQ2® Anesthetic Gas Monitor provides an affordable solution for 5-agent gas monitoring in any operating environment. The Poet IQ2 has an external video output port that is compatible with VGA flat screen displays, allowing patient data to be displayed where the surgical team needs to see the information. The anesthetic monitor comes with an internal high resolution color display that is designed into a compact, easy to use control panel that can fit into tight spaces. The internal display controls can be placed within easy reach while an external large screen display can be mounted where ever desired.
The Poet IQ2 automatically identifies and quantifies inspired and expired CO2, N2O, O2, and five anesthetic agents. The exceptional dynamic range of the advanced High IQ™ agent detector allows the monitor to accurately measure and display mixed gas measurements at low volumes.
The system's reliable performance, ease of use, flexible design, and affordable cost make it the ideal monitoring solution for anesthesia applications in hospitals and surgical centers.
Features & Benefits
▣ State-of-the-art NDIR technology identifies and measures five anesthetic agent gases:
▣ Halothane, Isoflurane, Enflurane, Sevoflurane, and Desflurane.
▣ Automatic and manual primary agent detection.
▣ Breath-by-breath CO2, O2, N2O monitoring.
▣ Gas flow sampled at 100, 150, and 200 ml/min.
▣ Mixed agent identification.
▣ Measurement accuracy is not affected by alcohol or metabolic ketones.
▣ Fast warm-up time ensures full accuracy within minutes.
▣ No user calibration required; minimal user interaction.
▣ Intuitive, easily configured user interface minimizes training and is ideal for multiple users.
▣ Bright, real-time display of numerical values and waveforms provides instant notification of changing patient status.
▣ Lightweight, portable design provides flexible workspace options.
Technical Specifications
▣ Gas Monitoring
▣ Method: Sidestream; Non-dispersive infra-red (NDIR)
▣ Identified Gases: Halothane, Isoflurane, Enflurane,
▣ Desflurane, Sevoflurane, CO2, N2O, Oxygen
▣ Concentration Units: Vol%, Torr, kPa, mmHg
▣ Flow Rates: 100 ml/min, 150 ml/min, 200 ml/min
▣ Occlusion Clearing: Automatic
▣ Auto Zeroing: Occurs 30 to 60 minutes
▣ Duration: 3.0 to 7.0 seconds
▣ Manual user calibration not required.
▣ TemPerature stabilized optical assembly.
Agent Detection
▣ Measurement Range:
▣ Halothane: 0 to 10%
▣ Isoflurane: 0 to 10%
▣ Enflurane: 0 to 10%
▣ Desflurane: 0 to 20%
▣ Sevoflurane: 0 to 10%
▣ CO2: 0 to 12.5%
▣ N2O: 0 to 99%
▣ Oxygen: 0 to 100%
Measurement Accuracy:
▣ Agents: ± (0.1% abs. + 4% reading)
▣ CO2: ± 0.2% abs. or 4% of reading
▣ N2O: ± (1.5% abs. + 4% of reading)
▣ Oxygen: ± 3 vol% (for 0-90%), ± 4 vol% (for 91-99%)
▣ Time to Detect Agent: < 15 seconds @ 200ml/min
▣ Agent Detection Resolution: 0.1 Volume Percent
▣ Mixed Gas Threshold: 0.2 vol. % +10% of total concentrations
▣ Rise Time:
▣ Agents: 450 msec
▣ CO2: 350 msec; N2O: 400 msec; Oxygen: 600 msec
Respiration Range
▣ Range: 1 to 60bpm
▣ Accuracy: ± 2bpm
System Features Display
▣ Main Display: Active color TFT
▣ Size: 5.9" Display Area
▣ Resolution: Internal Display; 320 x 240 pixels
▣ External Video; 640 x 480 pixels
▣ Number of Traces: 3 maximum
Controls
▣ Keys: 7; membrane-activated
▣ Rotary knob: Push and rotate; 24 steps/turn
System Outputs
▣ Com 2; Serial/Analog, mini-DIN8
▣ Com Ports: Com 1; RS 232-compatible, Serial DB-9
▣ Video Port: Color VGA compatible, High Density D-Sub 15
Trends
▣ Memory: 24 hours of tabular & graphic patient data
Power Requirements
▣ Voltage: 100, 120, 220, 240 VAC; 50/60 Hz
▣ Consumption: 40 W, typical
Mechanical
▣ Weight: 13 lbs. (5.9 kg.)
▣ Size: 6.5” (H) x 11.0” (W) x 12.0” (D);
▣ 16.5cm (H) x 27.94cm (W) x 30.48cm (D)
Environmental
▣ Operating Temperature: 15º to 35º C; 59º to 95º F
▣ Storage Temperature: -5º to 50º C; 23º to 122º F
▣ Operating/Storage Humidity: 15% to 95%, noncondensing
▣ Altitude: -1,000 to 10,000 ft. (-300m to 3000m)
▣ Type of Protection: Class I Equipment
▣ Degree of Protection: Type CF
▣ Protection against ingress: Ordinary
▣ Compatible with external VGA displays.
▣ External display not included.
GAS MONITORING ACCESSORIES
Sampling Devices
Catalog
Number Description
625N Sample Lines (Box of 25)
624 Disposable Nasal Cannula (Box of 10)
628 Divided Nasal Cannula (Box of 10)
616 Endotracheal Adaptor, Straight (Box of 10)
617 Endotracheal Adaptor, Elbow (Box of 10)
938F-NC WaterChek™ 2+ Water Trap (Box of 30)
644 Replacement O2 Cell
655 Scavenging Kit (Exhaust Line & Adaptor)
Calibration Accessories
Catalog
Number Description
621 Cal Gas Cylinder (5% CO2, Balance N2)
622 Cal Gas Cylinder (10% CO2, Balance N2)
716 Cal Gas Cylinder (95% O2, Balance CO2)
620 Cal Gas Cylinder (100% N2)
623 Hardware Regulator For Cylinder
613 Regulator Tubing
641 Cal Gas Aerosol (5% CO2, Bal N2)
642 Cal Gas Aerosol (10% CO2, Bal N2)
631 Cal Gas Aerosol (1% Isoflurane, 5% CO2, 60% N2O, Bal N2)
634 Cal Gas Aerosol (1% Enflurane, 5% CO2, 60% N2O, Bal N2)
635
Cal Gas Aerosol (1% Halothane, 5% CO2, 60% N2O, Bal N2)
1367 Cal Gas Aerosol (1% Sevoflurane, 5% CO2, 60% N2O, Bal N2)
1366 Cal Gas Aerosol (4% Desflurane, 5% CO2, 60% N2O, Bal N2)
Calibration Kits
Catalog
Number Description
612 CO2 only (Non-Anesthetic Agent)
5% CO2 cylinder, 10% CO2 cylinder, hardware regulator with
tubing, plastic storage case.
715 CO2 and O2 (Non-Anesthetic Agent)
5% CO2 cylinder, 10% CO2 cylinder, 95% O2 cylinder regulator
with tubing, plastic storage case.
1365 Anesthetic Agent Verification Kit (5 Agent)
One of each five aerosol agents, ISO, ENF, HAL, SEV, DES
as described above, includes plastic regulators with tubing.
909 Power Cord (Domestic US)
910UK Power Cord (United Kingdom)
910INT Power Cord (International)
910 Unterm Power Cord (Unterminated)
603 Japan Power Cord (Japan)