Search Our Store
- Cardiology Equipment
- Cardiac Rehabilitation
- Defibrillators | AED's
- EKG Machines
- Holter Monitoring Systems
- Stress Test Systems
- Telemetry Monitoring Systems
- Medical Treadmills
- Ultrasound Machines
- Medical Imaging
- C-Arms
- C-Arm Tables
- Ultrasound Machines
- Infusion Devices
- Infusion Pumps
- Syringe Pumps
- OB/GYN
- Colposcopes
- Fetal Monitors
- Patient Monitoring
- Patient Monitors
- Telemetry Monitoring Systems
- Respiratory Equipment
- Capnography
- Pulmonary Function Test Equipment
- Pulse Oximeters
- Spirometers
- Surgical Equipment
- Anesthesia Machines
- Autoclaves - Sterilizers
- Electrosurgical Units
- O2 Flowmeters
- OR Lights | Procedure Lights
- OR Tables
- Patient Monitors
- Ultrasonic Cleaners - Distillers
- Suction Regulators
- Suction Units
- Surgical Room Furniture
- Medical Cabinets
- Supply | Utility Carts
- Medical Case Carts
- Hampers & Receptacles
- Intravenous Stands
- Mayo | Solution Stands
- MRI - Safe Equipment
- Surgical Scrub Sinks
- Medical Exam Stools
- Stretchers
- Surgical Utensils
- Instrument | Back Tables
- Warming Cabinets
Home
Baxter Bard PCAII Syringe Pump
Service Directory
Baxter Bard PCAII Syringe PumpBaxter Bard PCAII Syringe Pump
View Complete SpecificationsQuick Specs!
Specifications
Mode of Operation:
- PCA
- Basal/PCA
- Continuous
Syringe Types:
- 50 ml Prefilled Syringe
- Monoject, 60 ml plastic
- B-D, 60 ml plastic
Flow Rates: 0.1 to 150 ml/hour, depending on the cartridge
Accuracy: Dose: ± 3% average linear displacement
Rate: ± 3% average linear rate
Occlusion Force: 9.5 ±1.3 lbs, equivalent to 11 psig nominal pressure
Front Panel Controls:
- Sealed tactile and audible feedback membrane switches:
- Start/Stop
- Enter
- Clear
- 0-9 and decimal point
- ON…
Specifications
Mode of Operation:
- PCA
- Basal/PCA
- Continuous
Syringe Types:
- 50 ml Prefilled Syringe
- Monoject, 60 ml plastic
- B-D, 60 ml plastic
Flow Rates: 0.1 to 150 ml/hour, depending on the cartridge
Accuracy: Dose: ± 3% average linear displacement
Rate: ± 3% average linear rate
Occlusion Force: 9.5 ±1.3 lbs, equivalent to 11 psig nominal pressure
Front Panel Controls:
- Sealed tactile and audible feedback membrane switches:
- Start/Stop
- Enter
- Clear
- 0-9 and decimal point
- ON and OFF switches inside the locking syringe cover.
Security Features: Locking syringe cover with key lock
Lockable IV pole clamp. Cartridge contained within locking syringe cover
Indicators: Description on the message panel: 8 lines x 14 characters Each, alphanumeric LCD
Batteries: Four D-size alkaline cells
Rechargeable
Battery Life: Alkaline: 600 hours typical (expected battery replacement period: 30 days)
Size: 13.0"H x 6.3"W x 2.8"D
Weight: 4.2 pounds with batteries
Environmental Use & Storage: Operation: 32 F to 122 F 0-90% rh (non-condensing)
Non-operational: -4 F to 140 F 0-95% rh (non-condensing)