Search Our Store
- Cardiology Equipment
- Ambulatory Blood Pressure Monitors
- Cardiac Rehabilitation
- Cardiac Rehab Treadmills
- Defibrillators | AED's
- EKG Machines
- Holter Monitoring Systems
- Stress Test Systems
- Telemetry Monitoring Systems
- Ultrasound Machines
- Medical Imaging
- C-Arms
- C-Arm Tables
- Ultrasound Machines
- Infusion Devices
- Infusion Pumps
- Syringe Pumps
- OB/GYN
- Colposcopes
- Fetal Monitors
- Patient Monitoring
- Patient Monitors
- Telemetry Monitoring Systems
- Respiratory Equipment
- Capnography
- Pulse Oximeters
- Soft-Touch Timeter Flowmeters
- Spirometers
- Timeter Classic Flowmeters
- Surgical Equipment
- Anesthesia Machines
- Autoclaves - Sterilizers
- Electrosurgical Units
- OR Lights | Procedure Lights
- OR Tables
- Patient Monitors
- Suction Equipment
- Suction Regulators
- Ultrasonic Cleaners - Distillers
- Surgical Room Furniture
- Medical Cabinets
- Supply | Utility Carts
- Medical Case Carts
- Hampers & Receptacles
- Intravenous Stands
- Mayo | Solution Stands
- MRI - Safe Equipment
- Surgical Scrub Sinks
- Medical Exam Stools
- Stretchers
- Surgical Utensils
- Instrument | Back Tables
- Warming Cabinets
Home
B. Braun Vista Basic Infusion Pump
Service Directory
B. Braun Vista Basic Infusion PumpB. Braun Vista Basic Infusion Pump
View Complete SpecificationsQuick Specs!
PRODUCT SPECIFICATIONS
Mechanism: Linear Peristaltic
Dimensions: 5.5"W x 9.4"H x 7.8"D
Weight: 6.8 lbs.
Power: 100-120 VAC, 50-60 Hz, 13 Watts
Battery: -7.2V, 1.2Ah NiCad rechargeable
Battery Operating Time: 3.5 hours at max delivery rate
Rate Range: 0.1-800 ml/hr in 0.1 ml increments with Vista™ tubing
Volume to be Infused: 0.1-9999.9 ml
Occlusion Pressure: Variable Settings: Low - 8 PSI, High - 17 PSI
KVO Rate: 1 ml/hr or selected rate whichever is lower
Flow Rate Accuracy: ±5%
Alarms…
PRODUCT SPECIFICATIONS
Mechanism: Linear Peristaltic
Dimensions: 5.5"W x 9.4"H x 7.8"D
Weight: 6.8 lbs.
Power: 100-120 VAC, 50-60 Hz, 13 Watts
Battery: -7.2V, 1.2Ah NiCad rechargeable
Battery Operating Time: 3.5 hours at max delivery rate
Rate Range: 0.1-800 ml/hr in 0.1 ml increments with Vista™ tubing
Volume to be Infused: 0.1-9999.9 ml
Occlusion Pressure: Variable Settings: Low - 8 PSI, High - 17 PSI
KVO Rate: 1 ml/hr or selected rate whichever is lower
Flow Rate Accuracy: ±5%
Alarms:
- Air-in-line
- Low Battery
- Plug in Now
- Bag Empty
- Downstream Occlusion
- Door Open
- Pump Stopped
- KVO
- Unit Malfunction
Mode/Features:
- Continuous and Piggyback Modes
- Program Mode for variable infusions
- Ramp/Taper Mode for TPN infusions
- Delay A Mode for postponing start and finish